Step 2: Complete the Pre-Install Checklist
Before we can send over a CNC Factory technician to install your machine, you will need to complete the pre-installation items below. By preparing it to a “ready to configure” state, you will be able to maximize your time with the technician in learning how to operate and maintain your machine in a safe environment.
After signing off on the checklist, send to support@cncfactory.com and you can now schedule your installation by calling 714-581-5999. Make sure to discuss exhaustively any installation concerns/questions during this call.
Electrical/Mechanical requirements of your machine
Select your machine below to see its requirements:
Electrical:
FOR ROUTER: 208-240 volts, 3 phase, 30 amps, 10 gauge wire
FOR EACH VACUUM PUMP: 208-240 volts, 3 phase, 50 amps, 6 gauge wire
•
Air:
FOR ROUTER & VACUUM PUMP: 120 psi recommended, 8 bar, 9 cfm
AIR LINE: Standard 3/8“ air hose from any hardware store, attached to a standard industrial coupler (male and female).
AIR COMPRESSOR: 5.0HP running, 155psi, 80 gallon
•
Dust Extraction:
CFM required for main (top) 6″ port: 2000cfm
Minimum recommended for Dust Extractor: 5HP – 10HP
Electrical:
FOR ROUTER: 208-240 volts, 3 phase, 30 amps, 10 gauge wire
FOR EACH ADDITIONAL TABLE (Loading or unloading): +5 amps per table
FOR EACH VACUUM PUMP: 208-240 volts, 3 phase, 50 amps, 6 gauge wire
•
Air:
FOR ROUTER & VACUUM PUMP: 120 psi recommended, 8 bar, 9 cfm
AIR LINE: Standard 3/8“ air hose from any hardware store, attached to a standard industrial coupler (male and female).
AIR COMPRESSOR: 5.0HP running, 155psi, 80 gallon
•
Dust Extraction:
CFM required for main (top) 6″ port: 2500cfm
For 2nd dust collector 4″ port: gravity
For (optional) unloading table 4″ port: gravity
Minimum recommended for Dust Extractor: 5HP – 10HP
Electrical:
FOR ROUTER: 208-240 volts, 3 phase, 30 amps, 10 gauge wire
FOR EACH ADDITIONAL TABLE (Loading or unloading): +5 amps per table
FOR EACH VACUUM PUMP: 208-240 volts, 3 phase, 50 amps, 6 gauge wire
•
Air:
FOR ROUTER & VACUUM PUMP: 120 psi recommended, 8 bar, 9 cfm
AIR LINE: Standard 3/8“ air hose from any hardware store, attached to a standard industrial coupler (male and female).
AIR COMPRESSOR: 5.0HP running, 155psi, 80 gallon
•
Dust Extraction:
CFM required for main (top) 6″ port: 2500cfm
For 2nd dust collector 4″ port: gravity
For (optional) unloading table 4″ port: gravity
Minimum recommended for Dust Extractor: 5HP – 10HP
Electrical:
FOR ROUTER: 208-240 volts, 3 phase, 30 amps, 10 gauge wire
FOR LOADING TABLE: +5 amps
FOR UNLOADING TABLE: +5amps
FOR EACH VACUUM PUMP: 208-240 volts, 3 phase, 50 amps, 6 gauge wire
•
Air:
FOR ROUTER & VACUUM PUMP: 120 psi recommended, 8 bar, 9 cfm
AIR LINE: Standard 3/8“ air hose from any hardware store, attached to a standard industrial coupler (male and female).
AIR COMPRESSOR: 5.0HP running, 155psi, 80 gallon
•
Dust Extraction:
CFM required for main (top) 6″ port: 2800cfm
For 2nd dust collector 4″ port: gravity
For (optional) unloading table 4″ port: gravity
Minimum recommended for Dust Extractor: 5HP – 10HP
For additional information on Dust Collection: